American Ductile Iron Pipe Home Page

Bends & Base Bends

AMERICAN Ductile Iron Mechanical Joint Fittings
ANSI/AWWA C110/A21.10 and C153/A21.53
90° Bends (1/4th)

90° | 45° | 22 1/2° | 11 1/4° | Base Bends

AWWA C110

ADIP Table No. 5-3

Size
in.
Pressure
Rating
psi
Dimensions in Inches Weight in Pounds
T A S R MJ & MJ MJ & PE
4 350 0.52 6.5 14.5 4.5 55 50
6 350 0.55 8 16 6 85 80
8 350 0.6 9 17 7 125 120
10 350 0.68 11 19 9 190 190
12 350 0.75 12 20 10 255 255
14 350 0.66 14 22 11.5 340 325
16 350 0.7 15 23 12.5 430 410
18 350 0.75 16.5 24.5 14 545 520
20 350 0.8 18 26 15.5 680 650
24 350 0.89 22 30 18.5 1025 985
30 250 1.03 25 33 21.5 1690 1585
36 250 1.15 28 36 24.5 2475 2310
42 250 1.28 31 39 27.5 3410 3200
48 250 1.42 34 42 30.5 4595 4330

Notes:
See General Notes.
See Flanged Fittings for reducing bends.

AWWA C153 - Compact

ADIP Table No. 5-4

Size
in.
Pressure
Rating
psi
Dimensions in Inches Weight in Pounds
T
nom.
A
nom.
S
nom.
MJ & MJ MJ & PE
4 350 0.34 4 9.5 23 26
6 350 0.36 5 11.5 44 48
8 350 0.38 6.5 12.5 61 68
10 350 0.4 7.5 13 94 107
12 350 0.42 9 14.5 124 141
14 350 0.47 11.5 19.5 220 220
16 350 0.5 12.5 20.5 264 254
18 350 0.54 14 22.0 410 405
20 350 0.57 15 23.0 505 564
24 350 0.61 17 25 586 710
30 250* 0.66 22.75 31.75 1060 995
36 250* 0.74 25.75 34.75 1550 1455
42 250* 0.82 29.25 38.25 2205 2055
48 250* 0.90 33.25 42.25 2990 2805

Notes:
See General Notes.
See Flanged Fittings for reducing bends.
*Based on performance testing per AWWA C153, AMERICAN can rate these fittings 350 psi. However, because of the more labor-intensive and labor-reliant assembly of the MJ joint and the substantial thrust restraint requirements for working pressures that high, we recommend push-on joint configurations (Fastite, Flex-Ring and Lok-Ring) for high-pressure applications.

Back to top


AMERICAN Ductile Iron Mechanical Joint Fittings
ANSI/AWWA C110/A21.10 and C153/A21.53
45° Bends (1/8th)

90° | 45° | 22 1/2° | 11 1/4° | Base Bends

AWWA C110

ADIP Table No. 5-5

Size
in.
Pressure
Rating
psi
Dimensions in Inches Weight in Pounds
T A S R MJ & MJ MJ & PE
4 350 0.52 4.0 12.0 4.81 50 45
6 350 0.55 5.0 13.0 7.25 75 70
8 350 0.6 5.5 13.5 8.44 110 105
10 350 0.68 6.5 14.5 10.88 155 155
12 350 0.75 7.5 15.5 13.25 215 215
14 350 0.66 7.5 15.5 12.06 270 255
16 350 0.7 8.0 16.0 13.25 340 320
18 350 0.75 8.5 16.5 14.5 420 395
20 350 0.8 9.5 17.5 16.88 530 500
24 350 0.89 11.0 19.0 18.12 755 715
30 250 1.03 15.0 23.0 27.75 1380 1275
36 250 1.15 18.0 26.0 35 2095 1930
42 250 1.28 21.0 29.0 42.25 2955 2745
48 250 1.42 24.0 32.0 49.5 4080 3815

Notes:
See General Notes.

AWWA C153 - Compact

ADIP Table No. 5-6

Size
in.
Pressure
Rating
psi
Dimensions in Inches Weight in Pounds
T
nom.
A
min.
S
min.
MJ & MJ MJ & PE
4 350 0.34 2 7.5 19 22
6 350 0.36 3 8.5 37 38
8 350 0.38 3.5 9 49 59
10 350 0.4 4.5 10 74 81
12 350 0.42 5.5 11 101 111
14 350 0.47 5 13 164 154
16 350 0.5 5.5 13.5 202 206
18 350 0.54 6 14.0 289 290
20 350 0.57 7 15.0 348 340
24 350 0.61 7.5 15.5 475 460
30 250* 0.66 10.5 19.5 780 715
36 250* 0.74 12.0 21.0 1135 1040
42 250* 0.82 14.0 23.0 1610 1460
48 250* 0.90 15.0 24.0 2090 1905

Notes:
See General Notes.
*Based on performance testing per AWWA C153, AMERICAN can rate these fittings 350 psi. However, because of the more labor-intensive and labor-reliant assembly of the MJ joint and the substantial thrust restraint requirements for working pressures that high, we recommend push-on joint configurations (Fastite, Flex-Ring and Lok-Ring) for high-pressure applications.

Back to top


AMERICAN Ductile Iron Mechanical Joint Fittings
ANSI/AWWA C110/A21.10 and C153/A21.53
22 1/2° Bends (1/16th)

90° | 45° | 22 1/2° | 11 1/4° | Base Bends

AWWA C110

ADIP Table No. 5-7

Size
in.
Pressure
Rating
psi
Dimensions in Inches Weight in Pounds
T A S R MJ & MJ MJ & PE
4 350 0.52 4 12 10.06 50 45
6 350 0.55 5 13 15.06 75 70
8 350 0.6 5.5 13.5 17.62 110 105
10 350 0.68 6.5 14.5 22.62 160 160
12 350 0.75 7.5 15.5 27.62 220 220
14 350 0.66 7.5 15.5 25.12 275 260
16 350 0.7 8 16 27.62 345 325
18 350 0.75 8.5 16.5 30.19 430 405
20 350 0.8 9.5 17.5 35.19 535 505
24 350 0.89 11 19 37.69 765 725
30 250 1.03 15 23 57.81 1400 1295
36 250 1.15 18 26 72.88 2135 1970
42 250 1.28 21 29 88 3020 2810
48 250 1.42 24 32 103.06 4170 3905

Notes:
See General Notes.

AWWA C153 - Compact

ADIP Table No. 5-8

Size
in.
Pressure
Rating
psi
Dimensions in Inches Weight in Pounds
T
nom.
A
min.
S
min.
MJ & MJ MJ & PE
4 350 0.34 1.5 7 17 21
6 350 0.36 2 7.5 33 37
8 350 0.38 2.5 8 44 51
10 350 0.4 3 8.5 64 67
12 350 0.42 3.5 9 85 80
14 350 0.47 3.75 11.25 148 152
16 350 0.5 3.75 11.75 179 181
18 350 0.54 4.5 12.5 292 290
20 350 0.57 4.5 12.5 364 345
24 350 0.61 4.5 12.5 385 455
30 250* 0.66 6.75 15.75 665 600
36 250* 0.74 7.75 16.75 960 865
42 250* 0.82 9.0 18.0 1350 1200
48 250* 0.90 10.0 19.0 1760 1575

Notes:
See General Notes.
*Based on performance testing per AWWA C153, AMERICAN can rate these fittings 350 psi. However, because of the more labor-intensive and labor-reliant assembly of the MJ joint and the substantial thrust restraint requirements for working pressures that high, we recommend push-on joint configurations (Fastite, Flex-Ring and Lok-Ring) for high-pressure applications.

Back to top


AMERICAN Ductile Iron Mechanical Joint Fittings
ANSI/AWWA C110/A21.10 and C153/A21.53
11 1/4° Bends (1/32nd)

90° | 45° | 22 1/2° | 11 1/4° | Base Bends

AWWA C110

ADIP Table No. 5-9

Size
in.
Pressure
Rating
psi
Dimensions in Inches Weight in Pounds
T A S R MJ & MJ MJ & PE
4 350 0.52 4 12 20.31 50 45
6 350 0.55 5 13 30.5 75 70
8 350 0.6 5.5 13.5 35.5 110 105
10 350 0.68 6.5 14.5 45.69 160 160
12 350 0.75 7.5 15.5 55.81 220 220
14 350 0.66 7.5 15.5 50.75 275 260
16 350 0.7 8 16 55.81 345 325
18 350 0.75 8.5 16.5 60.94 430 405
20 350 0.8 9.5 17.5 71.06 540 510
24 350 0.89 11 19 76.12 770 730
30 250 1.03 15 23 116.75 1410 1305
36 250 1.15 18 26 147.25 2145 1980
42 250 1.28 21 29 177.69 3035 2825
48 250 1.42 24 32 208.12 4190 3925

Notes:
See General Notes.

AWWA C153 - Compact

ADIP Table No. 5-10

Size
in.
Pressure
Rating
psi
Dimensions in Inches Weight in Pounds
T
nom.
A
min.
S
min.
MJ & MJ MJ & PE
4 350 0.34 1.25 6.25 16 19
6 350 0.36 1.5 7 31 32
8 350 0.38 1.75 7.25 40 44
10 350 0.4 2 7.5 57 60
12 350 0.42 2.25 7.75 73 76
14 350 0.47 2.5 10.5 129 137
16 350 0.5 2.5 10.5 162 161
18 350 0.54 3 13 196 280
20 350 0.57 3 14 227 335
24 350 0.61 3 14.5 345 450
30 250* 0.66 4.75 13.75 600 535
36 250* 0.74 5.0 14.0 840 745
42 250* 0.82 6.0 15.0 1180 1030
48 250* 0.90 6.5 15.5 1475 1290

Notes:
See General Notes.
*Based on performance testing per AWWA C153, AMERICAN can rate these fittings 350 psi. However, because of the more labor-intensive and labor-reliant assembly of the MJ joint and the substantial thrust restraint requirements for working pressures that high, we recommend push-on joint configurations (Fastite, Flex-Ring and Lok-Ring) for high-pressure applications.

Back to top


AMERICAN Ductile Iron Mechanical Joint Fittings
ANSI/AWWA C110/A21.10
Base Bends

90° | 45° | 22 1/2° | 11 1/4° | Base Bends

ADIP Table No. 5-22

Size
in.
Pressure
Rating
psi
Dimensions in Inches Weight in Pounds
R S
Dia.
T U MJ & MJ MJ & PE Base
Only
30 250 23 16 1.19 1.15 1880 1775 190
36 250 26 19 1.25 1.15 2725 2560 250
42 250 30 23.5 1.44 1.28 3820 3610 410
48 250 34 25 1.56 1.42 5110 4845 515

Notes:
See General Notes.

Back to top
 
 



 


 
 

© 1995 – 2008, American Cast Iron Pipe Company
Site Map | Contact Us