AMERICAN Ductile Iron Flex-Lok Boltless Ball Joint Pipe For Water, Sewage and Other Liquids 4"-24"
Standard Classes and Thicknesses
Standard Classes and Thicknesses | Technical Data | Laying Length Connecting Pieces | Closure Assembly | To Top of Page

The following table shows suggested water pressure ratings with thickness designations and weights in accordance with applicable requirements of ANSI/AWWA C150/A21.50 and ANSI/AWWA C151/A21.51. It is intended that the ultimate determination of suitable thicknesses should be made by the design engineer with consideration of both installation methods and ultimate service conditions of the line.
ADIP Table No. 10-1
Size
in. |
Laying
Length*
ft.-in. |
Working
Pressure**
psi |
T
Wall
Thickness***
in. |
Weight in Pounds |
Underwater Weight Per
Length Incl. Joint Materials+ |
Per Pipe
Length |
Per Length
Incl. Joint
Materials |
Per Foot
Incl. Joint
Materials |
Full of Air
lb. |
Full of Water
lb. |
| 4 |
20'-6" |
250 |
0.41 |
345 |
375 |
18.3 |
206 |
325 |
| 6 |
20'-6" |
250 |
0.43 |
605 |
645 |
31.5 |
302 |
555 |
| 8 |
20'-6" |
250 |
0.45 |
840 |
895 |
43.7 |
306 |
770 |
| 10 |
20'-6" |
250 |
0.47 |
1100 |
1170 |
57.1 |
284 |
1005 |
| 12 |
20'-6" |
250 |
0.49 |
1390 |
1480 |
72.2 |
231 |
1275 |
| 14 |
20'-6" |
250 |
0.51 |
1760 |
1880 |
91.7 |
193 |
1615 |
| 16 |
20'-6" |
250 |
0.52 |
2045 |
2200 |
107.3 |
15 |
1880 |
| 18 |
20'-6" |
250 |
0.53++ |
2425 |
2610 |
127.3 |
-129++ |
2245 |
| 20 |
20'-6" |
250 |
0.54++ |
2810 |
3040 |
148.3 |
-327++ |
2610 |
| 24 |
20'-6" |
250 |
0.56++ |
3605 |
3910 |
190.7 |
-889++ |
3360 |
Notes:
*The 20'-6" laying length is subject to trim pipe allowance in accordance with AWWA C151; also, this is the fully homed or inserted laying length of 4"-24" Flex-Lok pipe. In installations where 4"-24" joints are pulled or extended to metal-binding contact of joint-locking members, some slight additional laying length will be gained as a function of the removal of joint assembly space. Contact AMERICAN when lengths are critical, or when it is necessary to locate ball joints at specific stations, etc. The joints will seal properly in any axial position from fully homed to fully extended, and with any joint deflection angles up to the maximum rating.
**The working pressure is AMERICAN's suggested standard water working pressure. Contact AMERICAN if higher working pressure is involved.
***Thicknesses correspond to Special Class 56. Check AMERICAN if pipe with other wall thickness is required.
+Does not include lining weight. Underwater pipe weights are for fresh water. Sea water is approximately 3% heavier than fresh water, and these weights should be adjusted accordingly for sea water installation.
++When full of air, pipe of this thickness will float unless weight is added. See Table No. 11-1 for cement-lining weights. Gross weight, including pipe, gland and lining, is painted on each length of Flex-Lok pipe to aid in field calculations of actual buoyancy.
Flex-Lok Ball ends may be integrally cast or threaded-on, our option.
Technical Data
Standard Classes and Thicknesses | Technical Data | Laying Length Connecting Pieces | Closure Assembly | To Top of Page

ADIP Table No. 10-3
Size
in. |
A
in. |
N
in. |
Joint Materials
Weight in Pounds |
Lubricant
Pounds
Per Joint |
Maximum
Joint
Deflection |
Maximum
Safe
End Pull
in Tons+ |
| Gland |
Gasket |
Locking
Wedge |
Complete
Set |
| 4 |
4.8 |
11.79 |
27 |
1 |
1 |
29 |
0.09 |
15° |
21 |
| 6 |
6.9 |
13.91 |
37 |
1 |
1 |
39 |
0.12 |
15° |
35 |
| 8 |
9.05 |
16.38 |
50 |
1 |
2 |
53 |
0.16 |
15° |
49 |
| 10 |
11.1 |
18.84 |
67 |
1 |
3 |
71 |
0.27 |
15° |
63 |
| 12 |
13.2 |
21.56 |
89 |
1 |
3 |
93 |
0.4 |
15° |
76 |
| 14 |
15.3 |
24.43 |
115 |
2 |
3 |
120 |
0.5 |
15° |
90 |
| 16 |
17.4 |
26.78 |
147 |
3 |
4 |
154 |
0.6 |
15° |
100 |
| 18 |
19.5 |
29.7 |
181 |
3 |
4 |
188 |
0.75 |
15° |
110 |
| 20 |
21.6 |
32.59 |
221 |
4 |
4 |
229 |
0.9 |
15° |
119 |
| 24 |
25.8 |
37.29 |
297 |
5 |
4 |
306 |
1.1 |
15° |
130 |
Notes:
*Refer to Table No. 10-1 for thickness "T" dimensions.
+Check AMERICAN for greater end pull requirements.
Laying Length
Standard Classes and Thicknesses | Technical Data | Laying Length Connecting Pieces | Closure Assembly | To Top of Page

ADIP Table No. 10-5
Size
in. |
L.L.
Maximum
Laying
Length*
ft.-in. |
O.L.
Maximum
Overall
Length**
ft.-in. |
A
in. |
B
in. |
Bell Weight
lb. |
Ball Weight
lb. |
| 4 |
20'-6" |
20'-9 1/8" |
1.38 |
1.77 |
33 |
15 |
| 6 |
20'-6" |
20'-9 3/8" |
1.38 |
2.01 |
51 |
22 |
| 8 |
20'-6" |
20'-9 3/4" |
1.42 |
2.34 |
66 |
33 |
| 10 |
20'-6" |
20'-10" |
1.42 |
2.61 |
94 |
51 |
| 12 |
20'-6" |
20'-10 3/8" |
1.42 |
2.91 |
131 |
79 |
| 14 |
20'-6" |
20'-11" |
1.73 |
3.32 |
177 |
183 |
| 16 |
20'-6" |
20'-11 1/4" |
1.73 |
3.58 |
193 |
225 |
| 18 |
20'-6" |
20'-11 5/8" |
1.73 |
3.87 |
277 |
297 |
| 20 |
20'-6" |
21'-0 1/8" |
2.01 |
4.16 |
347 |
375 |
| 24 |
20'-6" |
21'-0 3/4" |
2.01 |
4.68 |
491 |
552 |
Notes:
*The maximum laying length (and accordingly the maximum overall length) is subject to trim pipe allowance in accordance with AWWA C151; also, this is the fully homed or inserted laying length of 4"-24" Flex-Lok pipe. In installations where 4"-24" joints are pulled or extended to metal-binding contact of joint locking members, some slight additional laying length will be gained as a function of the removal of joint assembly space. The joints will seal properly in any axial position from fully homed to fully extended, and with any joint deflection angles up to the maximum rating.
**Overall Length (O.L.) equals Laying Length L.L. + A + B.
Flex-Lok Ball ends may be integrally cast or threaded-on, our option.
ADIP Table No. 10-5 Part B Flex-Lok...
| Type Joints |
Maximum
Laying Length
ft.-in.*** |
Maximum
Overall Length
ft.-in. |
| Flex-Lok Socket and Flange Pipe |
19'-9" |
L.L. + A |
| Flex-Lok Socket and Plain End Pipe |
19'-9" |
L.L. + A |
| Flex-Lok Ball and Flange Pipe |
19'-6" |
L.L. + B |
| Flex-Lok Ball and Plain End Pipe |
20'-0" |
L.L. + B |
Notes:
***These lengths are generally applicable for 4"-24" Flex-Lok pipes. In pipe sizes greater than 12", AMERICAN may have capabilities to produce longer lengths. See Table 10-7 for similar 30"-54" configuration lengths, and please contact AMERICAN for specific longer lengths if desired.
Use formulas to obtain Overall Length corresponding to Maximum Laying Length or to any other required Laying Length.
Other joint combinations are available with Flex-Lok pipe, including Flex-Lok Ball and Ball in certain sizes. Check AMERICAN for further details on any desired combination.
Connecting Pieces
Standard Classes and Thicknesses | Technical Data | Laying Length Connecting Pieces | Closure Assembly | To Top of Page

ADIP Table No. 10-8
Size
in. |
T
Nominal Wall
Thickness*
in. |
Laying Length**
ft.-in. |
Weight of
Pipe Only
lb. |
Weight Incl.
Joint Materials
lb. |
| 4 |
0.44 |
2'-0" |
75 |
105 |
| 6 |
0.49 |
2'-0" |
115 |
155 |
| 8 |
0.51 |
2'-0" |
160 |
215 |
| 10 |
0.56 |
2'-0" |
220 |
290 |
| 12 |
0.49 |
2'-6" |
315 |
405 |
| 14 |
0.51 |
4'-6" |
600 |
720 |
| 16 |
0.55 |
4'-6" |
710 |
865 |
| 18 |
0.59 |
4'-6" |
915 |
1100 |
| 20 |
0.63 |
4'-6" |
1105 |
1335 |
| 24 |
0.68 |
4'-6" |
1510 |
1815 |
Notes:
Flex-Lok Connecting Pieces can be used to effect a change in direction in the shortest distance. They are used in lieu of Flex-Lok Bends.
*Thicknesses correspond to Special Class 56.
**Laying Lengths represent the minimum Laying Lengths of Flex-Lok Ball Joint Pipe.
Closure Assemblies
Standard Classes and Thicknesses | Technical Data | Laying Length Connecting Pieces | Closure Assembly | To Top of Page

ADIP Table No. 10-10
Size
in. |
Laying Lengths* |
Assembled Weight in Pounds |
Flex-Lok Ball
Assembly Closure |
Flex-Lok Socket
Assembly Closure |
Flex-Lok Ball
Assembly Closure |
Flex-Lok Socket
Assembly Closure |
| 4 |
2'-10" |
2'-10" |
135 |
120 |
| 6 |
2'-9" |
2'-10" |
205 |
185 |
| 8 |
2'-8" |
2'-10" |
305 |
270 |
| 10 |
2'-7" |
2'-10" |
415 |
370 |
| 12 |
2'-7" |
2'-10" |
590 |
505 |
| 14 |
3'-1" |
3'-0" |
720 |
590 |
| 16 |
3'-2" |
3'-0" |
910 |
760 |
| 18 |
3'-3" |
3'-1" |
1130 |
935 |
| 20 |
3'-4" |
3'-2" |
1385 |
1135 |
| 24 |
3'-5" |
3'-3" |
1910 |
1530 |
Notes:
*Laying Lengths shown exclude the bolted-on pulling flange.
Pulling flange contains 2 taps (1" taps for 4"-10" and 2" taps for 12"-54").
Flex-Lok Closure Assemblies are available on loan basis for use in installing lines by pulling and for testing of lines after installation. They are normally furnished in pairs, i.e., one Ball and Closed End Assembly and one Socket and Closed End Assembly.
Assembled weights include the bolted-on pulling flange.
|