American Ductile Iron Pipe Home Page

Standard Pressure Classes


American Ductile Iron Pipe
ANSI/AWWA C150/A21.50
and
ANSI/AWWA C151/A21.51
Standard Pressure Classes - Wall Thickness and Nominal Wall Thicknesses

To Top of Page

ADIP Table No. 3-8

Size
in.
Outside
Diameter
in.
Pressure Class
150 200 250 300 350
Nominal Thickness in inches
4 4.8 - - - - 0.25
6 6.9 - - - - 0.25
8 9.05 - - - - 0.25
10 11.1 - - - - 0.26
12 13.2 - - - - 0.28
14 15.3 - - 0.28 0.3 0.31
16 17.4 - - 0.3 0.32 0.34
18 19.5 - - 0.31 0.34 0.36
20 21.6 - - 0.33 0.36 0.38
24 25.8 - 0.33 0.37 0.4 0.43
30 32 0.34 0.38 0.42 0.45 0.49
36 38.3 0.38 0.42 0.47 0.51 0.56
42 44.5 0.41 0.47 0.52 0.57 0.63
48 50.8 0.46 0.52 0.58 0.64 0.7
54 57.56 0.51 0.58 0.65 0.72 0.79
60 61.61 0.54 0.61 0.68 0.76 0.83
64 65.67 0.56 0.64 0.72 0.8 0.87

Notes:
Pressure classes are defined as the rated water working pressure of the pipe in psi. The thicknesses shown are adequate for the rated water working pressure plus a surge allowance of 100 psi. Calculations result in net thicknesses and are based on a minimum yield strength in tension of 42,000 psi and 2.0 safety factor times the sum of working pressure and 100 psi surge allowance.
Thickness can be calculated for rated water working pressure and surges other than the above by use of equation 1 in ANSI/AWWA C150/A21.50.
AMERICAN Ductile Iron pipe is available for water working pressures greater than 350 psi. Check AMERICAN for details.
These are standard pressure classes as given in AWWA C150 and C151. AMERICAN can furnish any thickness in between these standard thicknesses if deemed economical for major projects.
AMERICAN Ductile Iron pipe is also available with thicknesses greater than Pressure Class 350. For special applications, contact AMERICAN.


 American Ductile Iron
FastiteĀ® Joint Pipe
ANSI/AWWA C151/A21.51
Weights for Pressure Classes

To Top of Page

ADIP Table No. 3-9

Size
in.
Pressure
Class

Wall
Thickness
in.
Weight in Pounds

Per Foot
Plain End
FASTITE JOINT

Per Foot Inc. Bell

Per Nominal* Length
4 350 0.25 10.9 11.3 206
6 350 0.25 16 16.7 335
8 350 0.25 21.1 22.1 445
10 350 0.26 27.1 28.4 570
12 350 0.28 34.8 36.4 730
14 250 0.28 40.4 43.2 865
14 300 0.3 43.3 46.1 925
14 350 0.31 44.7 47.6 955
16 250 0.3 49.3 52.5 1050
16 300 0.32 52.5 55.7 1115
16 350 0.34 55.8 59 1180
18 250 0.31 57.2 60.8 1220
18 300 0.34 62.6 66.3 1330
18 350 0.36 66.2 69.8 1400
20 250 0.33 67.5 71.5 1435
20 300 0.36 73.5 77.5 1555
20 350 0.38 77.5 81.5 1635
24 200 0.33 80.8 85.6 1715
24 250 0.37 90.5 95.3 1910
24 300 0.4 97.7 102.5 2055
24 350 0.43 104.9 109.7 2200
30 150 0.34 103.5 111.7 2240
30 200 0.38 115.5 123.7 2480
30 250 0.42 127.5 135.7 2720
30 300 0.45 136.5 144.7 2900
30 350 0.49 148.4 156.6 3140
36 150 0.38 138.5 149.2 2990
36 200 0.42 152.9 163.6 3280
36 250 0.47 170.9 181.6 3640
36 300 0.51 185.3 196 3930
36 350 0.56 203.2 213.9 4285
42 150 0.41 173.8 188.3 3765
42 200 0.47 198.9 213.3 4265
42 250 0.52 219.9 234.3 4685
42 300 0.57 240.7 255.2 5105
42 350 0.63 265.7 280.2 5605
48 150 0.46 222.6 240.3 4805
48 200 0.52 251.3 269 5380
48 250 0.58 280 297.7 5955
48 300 0.64 308.6 326.3 6525
48 350 0.7 337.1 354.8 7095
54 150 0.51 279.7 301.7 6035
54 200 0.58 317.7 339.7 6795
54 250 0.65 355.6 377.5 7550
54 300 0.72 393.4 415.3 8305
54 350 0.79 431.1 453.1 9060
60 150 0.54 317 346.4 6930
60 200 0.61 357.7 387.1 7740
60 250 0.68 398.3 427.7 8555
60 300 0.76 444.6 474 9480
60 350 0.83 485 514.4 10290
64 150 0.56 350.5 386.1 7720
64 200 0.64 400.1 435.7 8715
64 250 0.72 449.6 485.2 9705
64 300 0.8 498.9 534.5 10690
64 350 0.87 542 577.6 11550

Notes:
1. * 4" Fastite pipes are furnished in 18-foot nominal lengths – weights for all other sizes are for 20-foot nominal lengths.
2. Dimensions, lengths and weights, etc., are subject to change at our option.

Also see Standard Dimensions for Fastite Joint Pipe.

60" AMERICAN FastiteĀ® Joint Ductile Iron pipe being installed as a water transmission main.


 

AMERICAN Ductile Iron Pipe
for Water or Other Liquids
ANSI/AWWA C151/A21.51
Working Pressures and Maximum Depths of Cover
for Minimum Pressure Classes of Ductile Iron Pipe
4" - 64"

To Top of Page

ADIP Table No. 3-10

Size
in.
Pressure
Class
Thickness
in.
Working
Pressure (1)
psi
Laying Conditions
Maximum Depth of Cover in Feet(2)
Type 1 Type 2 Type 3 Type 4 Type 5
4 350 0.25 350 53 61 69 85 100(3)
6 350 0.25 350 26 31 37 47 65
8 350 0.25 350 16 20 25 34 50
10 350 0.26 350 11** 15 19 28 45
12 350 0.28 350 10** 15 19 28 44
14 250 0.28 250 * 11** 15 23 36
16 250 0.3 250 * 11** 15 24 34
18 250 0.31 250 * 10** 14 22 31
20 250 0.33 250 * 10 14 22 30
24 200 0.33 200 * 8** 12 17 25
30 150 0.34 150 * - 9 14 22
36 150 0.38 150 * - 9 14 21
42 150 0.41 150 * - 9 13 20
48 150 0.46 150 * - 9 13 20
54 150 0.51 150 * - 9 13 20
60 150 0.54 150 * 5** 9 13 20
64 150 0.56 150 * 5** 9 13 20

Notes:

  1. These pipes are adequate for the rated working pressure plus a surge allowance of 100 psi. Ductile iron pipe for working pressures higher than 350 psi is available. Figures include 2.0 safety factor times the sum of working pressure and 100 psi surge allowance.
  2. An allowance for single H-20 truck with 1.5 impact factor is included for all sizes and all depths of cover.
  3. Calculated maximum depth of cover exceeds 100'.

* Laying condition Type 1 is limited to 12" and smaller pipe. For 14" and larger pipe, laying condition Type 1 should not be used.
** Minimum allowable depth of cover is 3'.


AMERICAN Ductile Iron Pipe
for Water or Other Liquids
ANSI/AWWA C151/A21.51
Working Pressures and Maximum Depths of Cover
for Pressure Classes

To Top of Page

ADIP Table No. 3-11

Size
in.
Pressure (1)
Class
psi
Nominal
Thickness
in.
Laying Conditions
Maximum Depth of Cover in Feet (2)
Type 1 Type 2 Type 3 Type 4 Type 5
4 350 0.25 53 61 69 85 100 (3)
6 350 0.25 23 31 37 47 65
8 350 0.25 16 20 25 34 50
10 350 0.26 11** 15 19 28 45
12 350 0.28 10** 15 19 28 44
14 250 0.28 ++ 11** 15 23 36
14 300 0.3 ++ 13 17 26 42
14 350 0.31 ++ 14 19 27 44
16 250 0.31 ++ 11** 15 24 34
16 300 0.32 ++ 13 17 26 39
16 350 0.34 ++ 15 20 28 44
18 250 0.31 ++ 10** 14 22 31
18 300 0.34 ++ 13 17 26 36
18 350 0.36 ++ 15 19 28 41
20 250 0.33 ++ 10 14 22 30
20 300 0.36 ++ 13 17 26 35
20 350 0.38 ++ 15 19 28 38
24 200 0.33 ++ 8** 12 17 25
24 250 0.37 ++ 11 15 20 29
24 300 0.4 ++ 13 17 24 32
24 350 0.43 ++ 15 19 28 37
30 150 0.34 ++ - 9 14 22
30 200 0.38 ++ 8*** 12 16 24
30 250 0.42 ++ 11 15 19 27
30 300 0.45 ++ 12 16 21 29
30 350 0.49 ++ 15 19 25 33
36 150 0.38 ++ - 9 14 21
36 200 0.42 ++ 8*** 12 15 23
36 250 0.47 ++ 10 14 18 25
36 300 0.51 ++ 12 16 20 28
36 350 0.56 ++ 15 19 24 32
42 150 0.41 ++ - 9 13 20
42 200 0.47 ++ 8 12 15 22
42 250 0.52 ++ 10 14 17 25
42 300 0.57 ++ 12 16 20 27
42 350 0.63 ++ 15 19 23 32
48 150 0.46 ++ - 9 13 20
48 200 0.52 ++ 8 11 15 22
48 250 0.58 ++ 10 13 17 24
48 300 0.64 ++ 12 15 19 27
48 350 0.7 ++ 15 18 22 30
54 150 0.51 ++ - 9 13 20
54 200 0.58 ++ 8 11 14 22
54 250 0.65 ++ 10 13 16 24
54 300 0.72 ++ 13 15 19 27
54 350 0.79 ++ 15 18 22 30
60 150 0.54 ++ 5** 9 13 20
60 200 0.61 ++ 8 11 14 22
60 250 0.68 ++ 10 13 16 24
60 300 0.76 ++ 13 15 19 26
60 350 0.83 ++ 15 18 22 30
64 150 0.56 ++ 2** 9 13 20
64 200 0.64 ++ 8 11 14 21
64 250 0.72 ++ 10 13 16 24
64 300 0.8 ++ 12 15 19 26
64 350 0.87 ++ 15 17 21 29

Notes:

  1. These pipes are adequate for the rated working pressure indicated for each nominal size plus a surge allowance of 100 psi. Calculations are based on a 2.0 safety factor times the sum of working pressure and 100 psi surge allowance. Ductile iron pipe for working pressures higher than 350 psi is available.
  2. An allowance for a single H-20 truck with 1.5 impact factor is included for all sizes and all depths of cover.
  3. Calculated maximum depth of cover exceeds 100'.

++ Laying condition Type 1 is limited to 12" and smaller pipe. For 14" and larger pipe, laying condition Type 1 should not be used.
** Minimum allowable depth of cover is 3'.


AMERICAN Ductile Iron Fastite Joint Gravity Sewer Pipe
ASTM A746 PIPE WITH FLEXIBLE LININGS

Depths of Cover for Standard Pressure Classes

To Top of Page

ADIP Table No. 3-14

Size
in.
Pressure
Class
psi
Thickness
in.
Laying Conditions
Maximum Depth of Cover in Feet
Type 1 Type 2 Type 3 Type 4 Type 5
4 350 .25 53 61 69 85 109
6 350 .25 26 31 37 47 65
8 350 .25 16 20 25 34 50
10 350 .26 11** 15 19 28 45
12 350 .28 10** 15 19 28 44
14 250 .28 - 11** 15 23 41
14 300 .30 - 13 17 26 43
14 350 .31 - 14 19 27 44
16 250 .30 - 11** 15 24 41
16 300 .32 - 13 17 26 43
16 350 .34 - 15 20 28 45
18 250 .31 - 10** 14 23 40
18 300 .34 - 13 17 26 43
18 350 .36 - 15 19 28 45
20 250 .33 - 10* 14 23 40
20 300 .36 - 13 17 26 43
20 350 .38 - 15 19 28 44
24 200 .33 - 8** 12 20 37
24 250 .37 - 11 15 23 41
24 300 .40 - 13 17 26 43
24 350 .43 - 15 19 28 45
30 150 .34 - - 9** 17 33
30 200 .38 - 8** 12 20 37
30 250 .42 - 11 15 23 40
30 300 .45 - 12 16 25 42
30 350 .49 - 15 19 28 44
36 150 .38 - - 9 17 33
36 200 .42 - 8** 12 20 37
36 250 .47 - 10 14 23 40
36 300 .51 - 12 17 25 42
36 350 .56 - 15 19 28 45
42 150 .41 - - 9 16 32
42 200 .47 - 8 12 20 37
42 250 .52 - 10 14 23 40
42 300 .57 - 12 17 25 42
42 350 .63 - 15 19 28 45
48 150 .46 - - 9 17 33
48 200 .52 - 8 12 20 37
48 250 .58 - 10 14 23 40
48 300 .64 - 12 17 25 42
48 350 .70 - 15 19 28 44
54 150 .51 - - 9 17 33
54 200 .58 - 8 12 20 37
54 250 .65 - 10 14 23 40
54 300 .72 - 13 17 25 43
54 350 .79 - 15 19 28 45
60 150 .54 - 5** 9 17 33
60 200 .61 - 8 12 20 37
60 250 .68 - 10 14 23 40
60 300 .76 - 13 17 25 43
60 350 .83 - 15 19 28 45
64 150 .56 - 5** 9 17 33
64 200 .64 - 8 12 20 36
64 250 .72 - 10 15 23 40
64 300 .80 - 13 17 25 43
64 350 .87 - 15 19 28 45

Notes:
** Minimum allowable depth of cover is 3'.
The bolded numbers denote the depths of cover resulting from the pipe thickness being governed by deflection in the design; these covers are greater due to the design deflection of 5% for flexible-lined pipe instead of 3% for cement-lined pipe.

 

> Standard Pressure Classes-Wall Thickness
> Weights for Pressure Classes
> Working Pressures & Depths of Cover Min. Pressure Classes
> Working Pressures & Depths of Cover Pressure Classes
> Gravity Service Pipe Depths of Cover


 
 

© 1995 – 2008, American Cast Iron Pipe Company
Site Map | Contact Us