Flanged Fittings

Welded-on outlets are preferable in many cases to tees or crosses, especially for branch reductions. Consult AMERICAN or see Fabricated Items.

Size
(in.)
Pressure
Rating
(psi)
Dimensions in Inches Weight in
Pounds
Run Branch T T 1 H J Tee
4 4 250 0.52 0.52 6.5 6.5 65
6 4 250 0.55 0.52 8 8 100
6 6 250 0.55 0.55 8 8 105
8 4 250 0.6 0.52 9 9 145
8 6 250 0.6 0.55 9 9 150
8 8 250 0.6 0.6 9 9 165
10 4 250 0.68 0.52 11 11 220
10 6 250 0.68 0.55 11 11 230
10 8 250 0.68 0.6 11 11 240
10 10 250 0.8 0.8 11 11 285
12 4 250 0.75 0.52 12 12 315
12 6 250 0.75 0.55 12 12 320
12 8 250 0.75 0.6 12 12 335
12 10 250 0.87 0.8 12 12 380
12 12 250 0.87 0.87 12 12 405
141 4 250 0.66 0.52 14 14 375
14 6 250 0.66 0.55 14 14 385
14 8 250 0.66 0.6 14 14 400
14 10 250 0.66 0.68 14 14 415
14 12 250 0.66 0.75 14 14 445
14 14 250 0.66 0.66 14 14 455
161 4 250 0.7 0.52 15 15 475
16 6 250 0.7 0.55 15 15 485
16 8 250 0.7 0.6 15 15 500
16 10 250 0.7 0.68 15 15 515
16 12 250 0.7 0.75 15 15 540
16 14 250 0.7 0.66 15 15 550
16 16 250 0.7 0.7 15 15 575
181 4 250 0.75 0.52 13 15.5 495
18 6 250 0.75 0.55 13 15.5 500
18 8 250 0.75 0.6 13 15.5 515
18 10 250 0.75 0.68 13 15.5 530
18 12 250 0.75 0.75 13 15.5 555
18 14 250 0.75 0.66 16.5 16.5 655
18 16 250 0.75 0.7 16.5 16.5 675
18 18 250 0.75 0.75 16.5 16.5 695
201 4 250 0.8 0.52 14 17 625
20 6 250 0.8 0.55 14 17 630
20 8 250 0.8 0.6 14 17 645
20 10 250 0.8 0.68 14 17 660
20 12 250 0.8 0.75 14 17 685
20 14 250 0.8 0.66 14 17 690
20 16 250 0.8 0.7 18 18 840
20 18 250 0.8 0.75 18 18 850
20 20 250 0.8 0.8 18 18 885
241 4 250 0.89 0.52 15 19 875
24 6 250 0.89 0.55 15 19 880
24 8 250 0.89 0.6 15 19 890
24 10 250 0.89 0.68 15 19 905
24 12 250 0.89 0.75 15 19 930
24 14 250 0.89 0.66 15 19 930
24 16 250 0.89 0.7 15 19 950
24 18 250 0.89 0.75 22 22 1270
24 20 250 0.89 0.8 22 22 1305
24 24 250 0.89 0.89 22 22 1380
301 8 250 1.03 0.6 18 23 1450
301 10 250 1.03 0.68 18 23 1465
30 12 250 1.03 0.75 18 23 1485
30 14 250 1.03 0.66 18 23 1490
30 16 250 1.03 0.7 18 23 1505
30 18 250 1.03 0.75 18 23 1515
30 20 250 1.03 0.8 18 23 1540
30 24 250 1.03 0.89 25 25 2025
30 30 250 1.03 1.03 25 25 2150
361 8 250 1.15 0.6 20 26 2140
361 10 250 1.15 0.68 20 26 2150
36 12 250 1.15 0.75 20 26 2170
36 14 250 1.15 0.66 20 26 2175
36 16 250 1.15 0.7 20 26 2185
36 18 250 1.15 0.75 20 26 2190
36 20 250 1.15 0.8 20 26 2215
36 24 250 1.15 0.89 20 26 2255
36 30 250 1.15 1.03 28 28 3000
36 36 250 1.15 1.15 28 28 3165
421 10 250 1.28 0.68 23 30 3145
42 12 250 1.28 0.75 23 30 3165
42 14 250 1.28 0.66 23 30 3165
42 16 250 1.28 0.7 23 30 3180
42 18 250 1.28 0.75 23 30 3185
42 20 250 1.28 0.8 23 30 3205
42 24 250 1.28 0.89 23 30 3245
42 30 250 1.28 1.03 31 31 4130
42 36 150 1.28 1.15 31 31 4265
42 36 250 1.78 1.58 31 31 5365
42 42 150 1.28 1.28 31 31 4465
42 42 250 1.78 1.78 31 31 5580
481 10 250 1.42 0.68 26 34 4295
48 12 250 1.42 0.75 26 34 4315
48 14 250 1.42 0.66 26 34 4315
48 16 250 1.42 0.7 26 34 4325
48 18 250 1.42 0.75 26 34 4330
48 20 250 1.42 0.8 26 34 4350
48 24 250 1.42 0.89 26 34 4385
48 30 250 1.42 1.03 26 34 4455
48 36 250 1.42 1.15 34 34 5555
48 42 150 1.42 1.28 34 34 5720
48 42 250 1.96 1.78 34 34 7195
48 48 150 1.42 1.42 34 34 5900
48 48 250 1.96 1.96 34 34 7380
54 36 2502 1.05 1.15 31 37 4850
54 42 2502 1.05 1.28 39 39 5980
54 48 2502 1.05 1.42 39 39 6210
54 54 2502 1.05 1.05 39 39 6025
60 36 2502 1.1 1.15 33 42 6200
60 42 2502 1.1 1.28 43 43 7640
60 48 2502 1.1 1.42 43 43 7880
60 54 2502 1.1 1.05 43 43 7665
60 60 2502 1.1 1.1 43 43 8045
64 36 2502 1.16 1.15 32 44 7505
64 42 2502 1.16 1.28 48 45 9870
64 48 2502 1.16 1.42 48 45 10090
64 54 2502 1.16 1.05 48 46 9915
64 60 2502 1.16 1.1 48 46 10285
64 64 2502 1.16 1.16 48 48 10995

1 Not included in AWWA C110 or C153.

2 AMERICAN Standard. 54"-64" fittings are rated only 150 psi in AWWA C153.

Tee Reducing on Run

Size1
(in.)
Pressure
Rating
(psi)
Dimension in Inches Weight
(lbs.)
Run Branch T T 1 H K J
30 × 12 30 250 1.03 0.75 25 23 25 1880
30 × 20 30 250 1.03 0.8 25 23 25 1935
30 × 24 30 250 1.03 0.89 25 25 25 2025
36 × 12 36 250 1.15 0.75 28 26 28 2775
36 × 24 36 250 1.15 0.89 28 26 28 2860
36 × 30 36 250 1.15 1.03 28 28 28 3000
42 × 12 42 250 1.28 0.75 31 30 31 3950
42 × 24 42 250 1.28 0.89 31 30 31 3925
42 × 30 42 250 1.28 1.03 31 31 31 4130
42 × 36 42 250 1.28 1.15 31 31 31 4265
48 × 12 48 250 1.42 0.75 34 34 34 5305
48 × 42 48 250 1.42 1.28 34 34 34 5720
54 × 12 54 250 1.05 0.75 39 37 39 5360
54 × 36 54 250 1.05 1.15 39 37 39 5685
54 × 42 54 250 1.05 1.28 39 39 39 5980
54 × 48 54 250 1.05 1.42 39 39 39 6210

1 Tees reducing on run are generally available in 30" and larger sizes only.

Notes

  • Numerals on cuts indicate standard order of specifying size of fitting.
  • Additional combination reductions can be furnished. Center-to-face dimensions will be according to ANSI B16.1 class 125. See Standard Dimensions.
  • Other end combinations such as mechanical joint, Fastite, Lok-Ring or Flex-Ring can be furnished.

Tee Reducing on Run and Branch

Size1
(in.)
Pressure
Rating
(psi)
Dimension in Inches Weight
(lbs.)
Run Branch T T1 H K J
30 × 12 12 250 1.03 0.75 25 23 23 1610
30 × 12 20 250 1.03 0.8 25 23 23 1665
30 × 12 24 250 1.03 0.89 25 23 25 1755
30 × 20 12 250 1.03 0.75 25 23 23 1665
30 × 20 20 250 1.03 0.8 25 23 23 1715
30 × 20 24 250 1.03 0.89 25 23 25 1805
30 × 24 12 250 1.03 0.75 25 25 23 1755
30 × 24 20 250 1.03 0.8 25 25 25 1835
30 × 24 24 250 1.03 0.89 25 25 25 1895
36 × 12 12 250 1.15 0.75 28 26 26 2385
36 × 12 24 250 1.15 0.89 28 26 26 2470
36 × 12 30 250 1.15 1.03 28 26 28 2615
36 × 24 12 250 1.15 0.75 28 26 26 2385
36 × 24 24 250 1.15 0.89 28 26 26 2555
36 × 24 30 250 1.15 1.03 28 26 28 2695
36 × 30 12 250 1.15 0.75 28 28 26 2615
36 × 30 24 250 1.15 0.89 28 28 26 2695
36 × 30 30 250 1.15 1.03 28 28 28 2840
42 × 12 12 250 1.28 0.75 31 30 30 3430
42 × 12 24 250 1.28 0.89 31 30 30 3505
42 × 12 30 250 1.28 1.03 31 30 31 3610
42 × 24 12 250 1.28 0.75 31 30 30 3505
42 × 24 24 250 1.28 0.89 31 30 30 3580
42 × 24 30 250 1.28 1.03 31 30 31 3690
42 × 30 12 250 1.28 0.75 31 31 30 3610
42 × 30 24 250 1.28 0.89 31 31 30 3690
42 × 30 30 250 1.28 1.03 31 31 31 3795
48 × 12 12 250 1.42 0.75 34 34 34 4715
48 × 12 42 250 1.42 1.28 34 34 34 5130
48 × 42 12 250 1.42 0.75 34 34 34 5130
48 × 42 42 250 1.42 1.28 34 34 34 5540
54 × 12 12 250 1.05 0.75 39 37 37 4690
54 × 12 36 250 1.05 1.15 39 37 37 5015
54 × 12 42 250 1.05 1.28 39 37 39 5310
54 × 36 12 250 1.05 0.75 39 37 37 5015
54 × 36 36 250 1.05 1.15 39 37 37 5345
54 × 36 42 250 1.05 1.28 39 37 39 5635
54 × 42 12 250 1.05 0.75 39 39 37 5310
54 × 42 36 250 1.05 1.15 39 39 37 5635
54 × 42 42 250 1.05 1.28 39 39 39 5930

1 Tees reducing on runs and branches are available in 30" and larger sizes only.

Notes

  • Numerals on cuts indicate standard order of specifying size of fitting.
  • Additional combination reductions can be furnished. Center-to-face dimensions will be according to ANSI B16.1 class 125. See Standard Dimensions.
  • Other end combinations such as mechanical joint, Fastite, Lok-Ring or Flex-Ring can be furnished.

Bull-Head Tee

Size1 (in.) Pressure
Rating
(psi)
Dimension in Inches Weight
(lbs.)
Run Branch T T 1 H J
30 × 30 36 250 1.03 1.15 28 28 2840
30 × 30 54 250 1.03 1.05 37 39 5075
36 × 36 42 250 1.15 1.28 31 31 4060
36 × 36 54 250 1.15 1.05 37 39 5345
42 × 42 48 250 1.28 1.42 34 34 5540
42 × 42 54 250 1.28 1.05 39 39 5930
48 × 48 54 250 1.42 1.05 39 39 6400

1 Bull-head tees are available in 30" and larger sizes only.

Notes

  • Numerals on cuts indicate standard order of specifying size of fitting.
  • Additional combination reductions can be furnished. Center-to-face dimensions will be according to ANSI B16.1 class 125. See Standard Dimensions.
  • Other end combinations such as mechanical joint, Fastite, Lok-Ring or Flex-Ring can be furnished.

Side Outlet Tee

Flanged side outlet tees and crosses are available in 30"-48" sizes only and with flanged joints only.

Run &
Branch
Size (in.)
Side
Outlet
Size1 (in.)
Pressure
Rating
(psi)
Dimensions in Inches Weight
(lbs.)
Run &
Branch
Thickness
Side
Outlet
Thickness
Run &
Branch
Center-to-
Face
Side &
Outlet
Center-to-
Face2
30 16 250 1.03 0.70 25.0 23.0 2245
36 20 250 1.15 0.80 28.0 26.0 3280
42 24 250 1.78 0.89 31.0 30.0 5730
48 30 250 1.96 1.03 34.0 34.0 7595

Note: Numerals on cuts indicate standard order of specifying size of fitting.

1 Minimum sizes of side outlets are shown in table. For smaller sizes of outlets and for side outlets in 54"-64" fittings, flanged bosses – tapped for studs – can be furnished.

2 The center-to-face dimensions of all the side outlet fittings are according to ANSI B16.1 class 125. See Standard Dimensions.

Request More Information

Add specific model info if applicable

Tell us more

Print Page